Production OCPP 1.6-J & 2.0.1 Cloud CSMS
Zero proprietary hardware lock-in. Connect, supervise, and control compliant AC and DC charging stations with active stable support for both OCPP 1.6-J and OCPP 2.0.1 protocols.
Live OCPP 1.6-J WebSocket Stream (Simulated Demo)
wss://csms.chargedo.in/ocpp16/station_id
| Timestamp | Station Identifier | Direction | Action / Message | Inspect Payload |
|---|---|---|---|---|
| 12:14:02.184 | EXICOM_DC120_01 | INBOUND | BootNotification | |
| 12:14:02.210 | EXICOM_DC120_01 | OUTBOUND | BootNotificationResponse | |
| 12:14:05.412 | SERVOTECH_DC60_02 | INBOUND | StatusNotification | |
| 12:14:08.891 | SERVOTECH_DC60_02 | INBOUND | Authorize | |
| 12:14:08.920 | SERVOTECH_DC60_02 | OUTBOUND | AuthorizeResponse | |
| 12:14:12.002 | SERVOTECH_DC60_02 | INBOUND | StartTransaction |
Supported OCPP Protocol Messages
Full production support across OCPP 1.6-J and OCPP 2.0.1 message profiles.
| OCPP Action | Direction | Profile | Status | Engineering Implementation |
|---|---|---|---|---|
| BootNotification | EVSE → CSMS | Core (1.6-J & 2.0.1) | Implemented | Hardware registration, model string, serial validation, heartbeat interval configuration |
| Heartbeat | EVSE → CSMS | Core (1.6-J & 2.0.1) | Implemented | Keep-alive message stream used for real-time station online/offline monitoring |
| StatusNotification | EVSE → CSMS | Core (1.6-J & 2.0.1) | Implemented | Connector state changes (Available, Preparing, Charging, SuspendedEV, Faulted) |
| Authorize | EVSE → CSMS | Core (1.6-J & 2.0.1) | Implemented | RFID badge or virtual token validation against CPO driver database |
| StartTransaction | EVSE → CSMS | Core (1.6-J) | Implemented | Session initiation with initial meter value, connectorId, and driver token |
| StopTransaction | EVSE → CSMS | Core (1.6-J) | Implemented | Session termination with final meter value, total kWh, and disconnect reason |
| TransactionEvent | EVSE → CSMS | OCPP 2.0.1 Core | Implemented | Unified transaction lifecycle reporting (Started, Updated, Ended) with fine-grained trigger reasons |
| MeterValues | EVSE → CSMS | Core (1.6-J & 2.0.1) | Implemented | Periodic active power (kW), energy (kWh), voltage, current, and SoC telemetry stream |
| RemoteStartTransaction | CSMS → EVSE | Core (1.6-J & 2.0.1 RequestStartTransaction) | Implemented | App-initiated charge trigger from driver mobile app or admin console |
| RemoteStopTransaction | CSMS → EVSE | Core (1.6-J & 2.0.1 RequestStopTransaction) | Implemented | Driver app stop command or automated payment/tariff cutoff |
| Reset (Soft & Hard) | CSMS → EVSE | Core (1.6-J & 2.0.1) | Implemented | Remote station controller restart to clear transient controller faults |
| UnlockConnector | CSMS → EVSE | Core (1.6-J & 2.0.1) | Implemented | Emergency motorized cable release from CSMS admin dashboard |
| ChangeConfiguration / SetVariables | CSMS → EVSE | Config & Device Model | Implemented | Remote tuning of EVSE parameters and OCPP 2.0.1 component variables |
| GetConfiguration / GetVariables | CSMS → EVSE | Config & Device Model | Implemented | Diagnostic query of all supported configuration keys and device variables |
| SetChargingProfile | CSMS → EVSE | Smart Charging (1.6 & 2.0.1) | Implemented | Dynamic load modulation and time-of-day limits to prevent grid demand charge spikes |
| UpdateFirmware | CSMS → EVSE | Firmware Management | Implemented | Automated over-the-air firmware upgrades via secure HTTPS endpoints |
| CertificateSigned (ISO 15118) | CSMS ↔ EVSE | OCPP 2.0.1 Security | Implemented | Public key infrastructure for Plug & Charge automated vehicle authorization and mutual TLS |
Tested Hardware Models
Works with OCPP-compliant chargers. Tested with: Exicom, Servotech, Delta India, ABB, Schneider Electric, and [TODO: add tested charger models]. Contact us to verify yours.
Exicom
Tested in PilotDual-Gun DC Fast
Harmony DC Fast Series (60kW / 120kW)
Servotech
Tested in PilotCommercial Fast DC
Dual-Gun DC Series (30kW / 60kW)
Delta Electronics
Tested in PilotPublic AC / Fast DC
City Charger AC (22kW) & UFC Series
ABB
Tested in PilotDC Fast EVSE
Terra 54 / Terra DC Wallbox
Schneider Electric
Tested in PilotCommercial Destination
EVlink Commercial AC (7kW - 22kW)
[TODO: Tested OEM]
Verification UnderwayIn Testing
[TODO: add tested charger models]
Engineering Architecture: Modern Stack, Auto-Scaling & Tenant Isolation
ChargeDo is engineered from the ground up without legacy monolith baggage. Our infrastructure is optimized for high-frequency EV telemetry, multi-tenant security, and zero vendor lock-in.
Distributed WebSocket Gateway
Horizontally scalable Node.js / Go event routers handle persistent bidirectional OCPP WebSockets with automatic connection rebalancing and sub-second message dispatch.
Cryptographically Isolated Multi-Tenancy
Tenant data scoping at both the database and routing tiers guarantees CPO telemetry, driver records, and revenue splits remain strictly isolated with role-based access control.
Event Log Retention & Time-Series
MeterValues and status transitions are written to high-throughput time-series storage, enabling accurate kWh settlement, DISCOM sub-meter reconciliation, and instant debugging.
Developer REST APIs & Signed Webhooks
Seamlessly trigger transactions, query charger status, and listen to realtime lifecycle events.
POST https://api.chargedo.in/v1/sessions/remote-start
{
"station_id": "cs_hub_01",
"connector_id": 1,
"id_token": "USR_FLEET_9941"
}Event: session.completed [HMAC SHA-256]
{
"event": "session.completed",
"station_id": "cs_hub_01",
"kwh_delivered": 28.4,
"duration_seconds": 2140
}